50
Control Module
G1 SCBA 2018 Edition
US
9.2 Alarms
The PASS device is capable of indicating the following alarms. Use the Operating Manual: MSA A2
®
Software, Accountability Control Software (P/N 10162374) to configure optional alarms.
Alarm Type HUD Control Module Buddy Lights Sound
Motion pre-
alarm
Red atten-
tion, flashing
Red NFPA Pre-alarm
Motion/manual
full alarm
Red atten-
tion, solid
Red NFPA Full Alarm
Low pressure
alarm (EOSTI)
Red pres-
sure, flashing
Red Optional sound
Pressure drop
alarm
(optional)
Blue atten-
tion, flashing
Red Optional sound
Evacuate
(if equipped)
Red evacua-
tion, flashing
Red Sweep
Evacuation
confirmed (if
equipped)
Red evacua-
tion, solid
Red None
Overhaul
reminder
(optional)
Based on
pressure and
alarms
Based on pres-
sure and
alarms
None
Hardware
alarm
Red atten-
tion, flashing
Red NFPA Full Alarm

Table of Contents