Donning
GB
G1 Integrated SCBA System
6.3.2 Installing the Push-to-Connect LGDV
WARNING!
DO NOT use the SCBA unless the LGDV is connected properly. A LGDV that is not installed
correctly can separate from the full face mask unexpectedly.
Failure to follow these warnings can result in serious personal injury or death.
NOTE: If the SCBA passes all tests, it is ready for use. These tests must be performed every time
before entering a hazardous atmosphere. If the SCBA fails to meet any of the tests, the condi-
tion(s) must be corrected before using the SCBA.
(1) Grasp the LGDV and insert it into the full face mask
by pushing inward.
a) Check proper engagement by pulling on the
LGDV to ensure that the LGDV is securely
attached to full face mask.
(2) Check proper engagement by pulling on the LGDV
to ensure that the LGDV is securely attached to full
face mask.
(3) Inhale sharply to start the air flow.