Certification
GB
G1 Integrated SCBA System
Special conditions for safe use:
Properly donning and doffing of the self-contained breathing apparatus shall be done only in
non-hazardous areas.
Before entering the hazardous area, the complete self contained breathing apparatus elec-
tronics type G1 has to be checked for mechanical damages including the conductive ink layers
of the housings.
The disconnection of the alkaline battery pack and the changing of the batteries is only allowed
in non hazardous area.
Replace only batteries of the same type
The maximum RF radiation power of the antenna used for activation of the RFID Tag type
LOGI TAG 161 ICODE SLIX in hazardous areas shall not exceeded 2 W for Group IIC.
The ambient temperature range is - 30 °C Ta + 60 °C .
Quality Assurance Notification: 0080
Year of Manufacture: see Label
Serial No. see Label