31
Example: Stroke = 200 in., Resolution = 0.001 in.
Results: • Maximum Reading: 199.99 or 200 inches (See column 1)
• Digits: 5 1/4 (1 is considered 1/4 digit)
• Digital Counter Card Connections: Per column 4 (Pin Connections)
• Least Significant Digit (LSD) Connections: Pins 8, 7, 14, 13 (Card A)
• Most Significant Digit (MSD) Connections: Pin 12 (Card B)
The next MSD connections are Pins 8, 7, 14, 13 on Card B,
Pin 9 on Card A is NOT USED (see Note 3, below).
Resolution:
1/4 Digit, Pin 12 (Card B): 100
5th Digit: 10
4th Digit: 1
3rd Digit: 0.1
2nd Digit: 0.001
1st Digit: 0.001
Example Table: BCD Output Connection Table
1 2 3 4 5 6 7
Max. No. of Active Pin Connectors Binary Digit Check Appropriate
Reading Active Bits Digits Card A Card B Weight Column Resolution
other
8 1 1
7 2 (LSD)
1
14 4 0.000 0.001 0.01
1 13 8
12 1 2
11 2
18 4 0.001 0.01
0.1
2 17 8
16 1 3
15 2
20 4 0.01 0.1
1
999 12 3 21 8
1999 13 3 1/4 22 1 4
3999 14 3 1/2 19 2
7999 15 3 3/4 23 4 0.1 1
10
9999 16 4 25 8
19999 17 4 1/4 9
3
8 1 5
39999 18 4 1/2 7 2
79999 19 4 3/4 14 4 1 10
100
99999 20 5 13 8
199999
21 5 1/4 12 1 6
399999 22 5 1/2 11 2 (MSD)
2
799999 23 5 3/4 18 4 10 100 1000
999999 24 6 17 8
NOTES:
1. LSD = Least Significant Digit
2. MSD = Most Significant Digit
3. Used ONLY with 4 1/4 digits. For 4 1/2 digits or more, a second Digital Counter Card is required (5th digit is on second card).

Other manuals for MTS Systems Temposonics II LDT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems Temposonics II LDT and is the answer not in the manual?

MTS Systems Temposonics II LDT Specifications

General IconGeneral
BrandMTS Systems
ModelTemposonics II LDT
CategoryTransducer
LanguageEnglish