4.2 12/16/18V2000G65-TB engine data, fuel optimized
Explanation
Abbr. Meaning
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power settings).
N Not yet defined value
- Not applicable
X Applicable
** Not sufficiently validated value (tolerance +/- 5%)
Reference condition
Description 12V2000
G65-TB
16V2000
G65-TB
18V2000
G65-TB
Application group 3A 3A 3A
Intake air temperature °C 25 25 25
Charge air coolant temperature °C 55 55 55
Raw water inlet temperature °C - - -
Barometric pressure mbar 1000 1000 1000
Site altitude above sea level M 100 100 100
Power-related data (power ratings are net brake power as per ISO 3046)
Description 12V2000
G65-TB
16V2000
G65-TB
18V2000
G65-TB
Rated engine speed A rpm 1500 1500 1500
Continuous power ISO 3046 (10% overload pos-
sible) (power range DIN 6280, ISO 8528)
A kW 515 655 720
General conditions (for maximum power)
Description 12V2000
G65-TB
16V2000
G65-TB
18V2000
G65-TB
Intake depression (new filter) A mbar 15 15 15
Intake depression, max. L mbar 50 50 50
Exhaust overpressure A mbar 30 30 30
Exhaust gas overpressure, max. L mbar 85 85 85
MS15018/03E 2016-02 | Technical Data | 27
TIM-ID: 0000010846 - 002