8.7.4 Fuel system – Venting
Preconditions
Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use Part No. Qty.
Engine oil
WARNING
Fuels are combustible and explosive.
Risk of fire and explosion!
Avoid open flames, electrical sparks and ignition sources.
Do not smoke.
Wear protective clothing, protective gloves, and safety glasses / facial protection.
Venting fuel system
1. Unlock fuel priming pump, unscrew handle.
2. Loosen nut (arrowed) on banjo union.
3. Operate the pump with the handle until bub-
ble-free fuel emerges.
4. Tighten nut on banjo union.