Fault type – fault message text
SE no. Error message text
0 Sensor Temperatur Defect
1 Temperature failure
2 Sensor Voltage Defect
3 Voltage failure
4 CAN Bus- 1 Error/Bus Defec
5 CAN Bus- 1 Overrun
6 CAN Bus- 2 Error/Bus Defec
7 CAN Bus- 2 Overrun
8 Temperatur Compensation Error
9 I/O-Module Slot2 Defect
10 I/O-Module Slot3 Defect
11 I/O-Module Slot4 Defect
12 Serial Conection Lost
13 CAN Bus- 3 Error/Bus Defec
14 CAN Bus- 3 Overrun
15 S/A Bus Faulty
16 PAN 1 Defect
17 PAN 2 Defect
18 PAN 3 Defect
19 PAN 4 Defect
20 PAN 5 Defect
21 PAN 6 Defect
22 I/O-Module Slot1 Defect
23 I/O-Module Slot5 Defect
24 I/O-Module Slot6 Defect
25 I/O-Module Slot7 Defect
26 I/O-Module Slot8 Defect
27 Download Server Collision
28 not projected node
Engine governor messages
Recommended action in case of alarm
Yellow alarm:
The engine can still be operated providing that automatic engine shutdown to protect the engine has not
been configured or is not tripped. Contact Service immediately/start fault rectification.
Red alarm:
Caution, the engine is running at its limits. Shut down manually without further delay if the engine does not
shut itself down immediately after a red alarm is signaled.
Fault and alarm messages
The fault code numbers are generated by the engine governor and transmitted to the display below.
44 | Troubleshooting |
MS15018/03E 2016-02
TIM-ID: 0000008508 - 003