7.22.5 Engine Monitoring Unit EMU 8 – Plug connections check
Preconditions
ā˜‘ Engine is stopped and starting disabled.
Checking EMU plug connections
1. Check both connectors on EMU (2) for firm
seating. Ensure that the clips (1) are engag-
ed.
2. Check screws (3) of cable clamps on EMU (2)
for firm seating. Ensure that cable clamps are
not faulty.
148 | Accessories for (Electronic) Engine Governor / Control System | MS150119/01E 2016-02