Loading...
6.16 Raw Water Pump with Connections
6.16.1 Raw water pump – Relief bore check
Preconditions
☑ Engine is stopped and starting disabled.
DANGER
Unguarded rotating and moving engine components.
Risk of serious injury – danger to life!
• Take special care when working on a running engine.
WARNING
Engine noise above 85 dB (A).
Risk of damage to hearing!
• Wear ear protectors.
Raw water pump – Relief bore
check
1. Check relief bore for oil and coolant dis‐
charge.
2. Clean relief bore using a wire if required.
• Permissible coolant discharge: up to 10
drops per hour;
• Permissible oil discharge: up to 5 drops
per hour.
3. If discharge exceeds the specified limits,
contact Service.
MS150031/03E 2011-10 | Task Description | 165
TIM-ID: 0000007281 - 001