3.3 Putting the engine into operation after scheduled out-of-
service period
Preconditions
Engine is stopped and starting disabled.
Putting into operation
Item Task
Lube oil system Check oil level (→ Page 146).
Cooling system Check coolant level (→ Page 159).
Cooling system Preheat coolant with preheating unit.
Fuel prefilter Drain (→ Page 136).
Battery-charging generator
drive
Check condition of drive belt (→ Page 166).
Engine control system Switch ON.
Press READY FOR OPERATION button (→ Page 85).
LOP Press LAMP TEST button (→ Page 85).
88 | Operation | MS150031/03E 2011-10