EasyManua.ls Logo

MTU 8 V 2000 M40A - Page 32

MTU 8 V 2000 M40A
195 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RAW WATER CIRCUIT (open circuit)
Number of cylinders 8
Raw water pump: Inlet pressure, min. L bar -0.2
Raw water pump: Inlet pressure, max. L bar +0.5
Pressure loss in external raw water system, max. L bar 1.0
LUBE OIL SYSTEM
Number of cylinders 8
Lube-oil operating temperature before engine, from R °C 70
Lube oil operating temperature before engine, to R °C 75
Lube oil operating pressure before engine, from R bar 4.8
Lube oil operating pressure before engine, to R bar 5.3
Lube oil operating pressure (low idle) (meas. point: before engine) R bar 2.0
FUEL SYSTEM
Number of cylinders 8
Fuel pressure at engine supply connection, min. (when engine is starting) L bar -0.3
Fuel pressure at supply connection to engine, min. (when engine is run‐
ning)
L bar -0.3
Fuel pressure at engine supply connection, max. (when engine is starting) L bar +0.5
Fuel supply flow, max. R liter/min 1.3
GENERAL OPERATING DATA
Number of cylinders 8
Firing speed, from R rpm 100
Firing speed, to R rpm 120
STARTING (electric)
Number of cylinders 8
Starter, rated voltage (standard design) R V= 24
STARTING SYSTEM (with air/hydraulic starter motor)
Number of cylinders 8
Starting air pressure before starter motor, min. R bar 18*
Starting air pressure before starter motor, max. R bar 30
32 | Product Summary | MS150031/03E 2011-10
TIM-ID: 0000010982 - 001

Table of Contents

Related product manuals