RAW WATER CIRCUIT (open circuit)
Number of cylinders 12
Raw water pump: inlet pressure, min. L bar -0.2
Raw water pump: inlet pressure, max. L bar +0.5
Pressure loss in external raw water system, max. L bar 1.0
LUBE OIL SYSTEM
Number of cylinders 12
Lube oil temperature before engine, from R °C 73
Lube oil temperature before engine, to R °C 78
Lube oil operating pressure before engine, from R bar 7.5
Lube oil operating pressure before engine, to R bar 8.5
Lube oil operating pressure, low idle (meas. point: before engine) R bar 3.5
FUEL SYSTEM
Number of cylinders 12
Fuel pressure at supply connection on engine, min. (when engine is start‐
ing)
L bar -0.3
Fuel pressure at supply connection on engine, min. (when engine is run‐
ning)
L bar -0.3
Fuel pressure at supply connection on engine, max. (when engine is start‐
ing)
L bar +0.5
Fuel supply flow, max. R liter/min 2.7
GENERAL OPERATING DATA
Number of cylinders 12
Firing speed, from R rpm 100
Firing speed, to R rpm 120
STARTING (electric)
Number of cylinders 12
Rated starter voltage (standard design) R V= 24
STARTING (pneumatic starter)
Number of cylinders 12
Starting-air pressure before starter motor, min. R bar 21
Starting-air pressure before starter motor, max. R bar 30
44 | Product Summary | MS150031/03E 2011-10
TIM-ID: 0000002959 - 001