EasyManua.ls Logo

MTU 8 V 2000 M40A - Page 47

MTU 8 V 2000 M40A
195 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RAW WATER CIRCUIT (open circuit)
Number of cylinders 12
Raw water pump: inlet pressure, min. L bar -0.2
Raw water pump: inlet pressure, max. L bar +0.5
Pressure loss in external raw water system, max. L bar 1.0
LUBE OIL SYSTEM
Number of cylinders 12
Lube oil temperature before engine, from R °C 70
Lube oil temperature before engine, to R °C 75
Lube oil operating pressure before engine, from R bar 7.5
Lube oil operating pressure before engine, to R bar 8.5
Lube oil operating pressure, low idle (meas. point: before engine) R bar 3.5
FUEL SYSTEM
Number of cylinders 12
Fuel pressure at supply connection on engine, min. (when engine is start‐
ing)
L bar -0.3
Fuel pressure at supply connection on engine, min. (when engine is run‐
ning)
L bar -0.3
Fuel pressure at supply connection on engine, max. (when engine is start‐
ing)
L bar +0.5
Fuel supply flow, max. R liter/min 2.6
GENERAL OPERATING DATA
Number of cylinders 12
Firing speed, from R rpm 100
Firing speed, to R rpm 120
STARTING (electric)
Number of cylinders 12
Rated starter voltage (standard design) R V= 24
STARTING (pneumatic starter)
Number of cylinders 12
Starting-air pressure before starter motor, min. R bar 21
Starting-air pressure before starter motor, max. R bar 30
MS150031/03E 2011-10 | Product Summary | 47
TIM-ID: 0000002984 - 001

Table of Contents