RAW WATER CIRCUIT (open circuit)
Number of cylinders 16
Raw water pump: Inlet pressure, min. L bar -0.2
Raw water pump: Inlet pressure, max. L bar +0.5
Pressure loss in external raw water system, max. L bar 1.0
LUBE OIL SYSTEM
Number of cylinders 16
Lube-oil operating temperature before engine, from R °C 80
Lube oil operating temperature before engine, to R °C 85
Lube oil operating pressure before engine, from R bar 6.0
Lube oil operating pressure before engine, to R bar 7.0
FUEL SYSTEM
Number of cylinders 16
Fuel pressure at engine supply connection, min. (when engine is starting) L bar -0.3
Fuel pressure at supply connection to engine, min. (when engine is run‐
ning)
L bar -0.3
Fuel pressure at engine supply connection, max. (when engine is starting) L bar +0.5
Fuel supply flow, max. R liter/min 4.2
GENERAL OPERATING DATA
Number of cylinders 16
Firing speed, from R rpm 100
Firing speed, to R rpm 120
STARTING (electric)
Number of cylinders 16
Starter, rated voltage (standard design) R V= 24
STARTING SYSTEM (with air/hydraulic starter motor)
Number of cylinders 16
Starting air pressure before starter motor, min. R bar 24*
Starting air pressure before starter motor, max. R bar 30
MS150031/03E 2011-10 | Product Summary | 71