4.2 Preparation for startup after extended out-of-service periods
(>3 months)
Preconditions
Engine is stopped and starting disabled.
MTU Fluids and Lubricants Specifications (A001063/..) are available.
Startup after long out-of-service periods (>3 months)
Item Action
Engine Depreserve (→ MTU Fluids and Lubricants Specifications A001063/..).
Lube oil system Check engine oil level (→ Page 46).
Fuel system Vent (→ Page 41).
Coolant circuit If engine is out of service for more than one year, change engine coolant
(→ Page 50).
Change charge-air coolant (→ Page 57).
Coolant circuit Check engine coolant level (→ Page 49);
Check charge-air coolant level (→ Page 56).
Coolant circuit Preheat engine coolant with coolant preheating unit (if fitted).
Engine governor Check plug-in connections (→ Page 64).
Engine control system Switch on.