7.3.2 Fuel prefilter – Drain condensate
Preconditions
Engine is stopped and starting disabled.
WARNING
Fuels are combustible.
Risk of fire and explosion!
Avoid open flames, electrical sparks and ignition sources.
Do not smoke.
Draining condensate from fuel
prefilter
1. Provide a suitable container to collect the
water.
2. Open drain screw (1).
3. Allow water to drain off.
4. Screw in and close drain screw (2).