4.5 Stopping the engine
Preconditions
Engine is not connected to load.
CAUTION
Stopping the engine when it is running at full load causes extreme stress to the engine.
Risk of overheating, damage to components!
Before stopping the engine, operate it at idle speed until operating temperatures decrease and
stable values are indicated.
Stopping the engine
Item Action
Temperature indications Wait until engine temperatures are constant.
Switchgear cabinet, control
panel etc. (depending on
manufacturer)
Press stop button.
Automatic stopping procedure is performed.
Engine at a standstill.
28 | Operation | MS15025/00E 2011-12