MI.NET MULTI-NETWORK COLLECTOR
18
Installation and Operation Manual
Figure 9: Collector Base Unit and TTU remote antenna assembly antenna not pictured
LIGHTNING PROTECTION AND GROUNDING
To provide adequate levels of surge protection during an electrical storm, implement proper grounding techniques during
installation. See Appendix III: Lightning Protection Recommendations for additional information and installation requirements in
lightning-prone locations.
The base unit’s lightning arrestor includes a dedicated grounding point (labeled GND in Figure 3). The lightning arrestor ground
must
be connected to earth ground through a very low impedance connection, such as wire braid or large gauge copper wire
according to local electrical code. The remote amplifier provides a dedicated grounding screw which must be utilized.