EasyManuals Logo

Multiplex N2-Fusion ND21TS00 User Manual

Multiplex N2-Fusion ND21TS00
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
14 Part Number: 9290312 October/22/2018
Installation Section 2
NITROGEN CONNECTIONS & PRESSURES
1. Set inlet from food grade nitrogen tank to back of the
dispenser to 85 - 90 psi
(.586 - .621 MPa, 586 - 621 kPa, 5.86 - 6.21 bar).
Line OUT
Pressure to Unit
Line IN
N Tank Pressure
n
Warning
Line Out Pressure
Do Not exceed 90 psi
(.621 MPa, 621 kPa, 6.21 bar)
to the unit!
N
2
QUICK DISCONNECT & DRAIN
,
Caution
Installer should always check the locking collars on the
taps are tight prior to connecting the Nitrogen supply
line. If these collars are loose they can leak at the tower
shank when pressurized.
Flow
Control
Locking
Collar
Important
All plumbing must conform to local, state and national
codes.
2. Hook up nitrogen supply line to quick disconnect.
3. Run drip pan drain line and purge tube to floor drain.
N
2
Supply
Connection
Drain Line
Floor Drain
N
2
Purge Tube
2" Air Gap
NOTE: Purge tube releases under pressure, make sure it is
fastened down.
4. Ensure drain line is not kinked or otherwise blocked for
proper drainage.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Multiplex N2-Fusion ND21TS00 and is the answer not in the manual?

Multiplex N2-Fusion ND21TS00 Specifications

General IconGeneral
BrandMultiplex
ModelN2-Fusion ND21TS00
CategoryBeverage Dispenser
LanguageEnglish

Related product manuals