Page 7
CONTROL FUNCTION
RLY-OFF
RLY-ON
delay delay delay
Time Time Time
RLY-ON
RLY-ON
RLY-ON
RLY-OFF
RLY-OFF
RLY-OFF
Temp.
Temp.
S.V
HYST
HYST
S.V
Time
Time
OFF
OFF OFF OFF
OFF
ON - OFF control (Heating)
ON - OFF control (Cooling)
ON
ON ON ON
ON
Alarm 3
Outband
Low Alarm
Setpoint 3 Mode
Output 3 Mode
Low Set Point 3
High Set Point 3
Set 3 Mode
Hysterisis 3
Set Point 1 For O/P 1
Set Point 2 For O/P 2
Low Set Point 2
High Set Point 2
Password
Input ( Sensor )
Set Low Limit
Set High Limit
Offset
Proportional Band For PID Action
Integral Time Constant
Derivative Time Constant
Cycle Time For PID Action
Manual Reset
Cooling PB
Cooling On Time
Cooling Off Time
Hysterisis 1
Hysterisis 2
Output 1 Mode
Alarm 2
Set 2 Mode
Relay 1 Delay Time
Relay 2 Delay Time
PID Action
ON-OFF Action
Blower TP Action
High Alarm
Absolute Low Alarm
In Band Alarm
Absolute Out Band Alarm
Heating Mode
Cooling Mode
Alarming Mode
OFF Mode
Yes
No
Set 2 Individual to Set 1
Set 2 Reletive to Set 1
Factory Setting
Control Action 1
Output 2 Mode
Control Action 2
Auto Tuning:-
The Auto-tuning function automatically computes
and sets the Proportional band (Pb) , Integral time (It),
Derivative time (dt), and cycle time as per process
characteristics.
Tuning LED will turn “ON” during Auto-Tuning
If the power goes off before auto-tuning is completed,
auto-tuning will be restarted at next power ON.
PID AUTO-TUNING
Press key for 6 sec to start/stop
PID auto-tuning
°C
PV
SV
TUNE
OUT
1
.
PARAMETER MESSAGE DESCRIPTION