Quick Reference Guide
58
disconnects. The 0 default
equals 50 ms.
S30
1 min. 0, 1–255 0 Sets how long the modem
waits after the last character
is received or transmitted
before it disconnects. The 0
default disables the timer.
S32
100 ms 0–255 20 Sets the time the modem
will wait for a RETURN to
be entered during escape
sequence execution.
S34
1 char- 0–60 10 Sets the number of com-
acter mand characters allowed
after +++AT.
S36
1 sec. 0, 1-255 5 Sets the time between DTR
inactive and modem off-
hook. S36=0 disables DTR
busy-out.
S37
1 sec. 0-255 5 Sets the time between DTR
active and modem on-hook.
S43
decimal 28, 26, 0 Sets fixed V.34 connect
24, 21, speed. 28 = 28800 bps;
19, 16, 26 = 26400 bps;. . . 48 =
14, 12, 4800 bps. 0 default disables
96, or 48 this feature.
S48
decimal 33, 31, 0 Sets maximum V.34 connect
28, 26, speed. 33 = 33600 bps;
24, 21, 31 = 31200 bps;. . . 48 =
19, 16, 4800 bps. 0 default disables
14, 12, feature (same as S48=33).
96, or 48
Register Unit Range Default Description