Loading...
Language: English (EN) - Original operating manual
Order number: P100-P-WO-0005663.3-EN-ER
Instruction manual
Chamber machine P100
MCB01
Serial number:
.........................................................
Service address: Manufacturer:
MULTIVAC
Sepp Haggenmüller GmbH & Co. KG
Bahnhofstraße 4
D-87787 Wolfertschwenden, Germany
Tel.: 0049 8334 601 0
www.multivac.com
Date: 11.06.2014
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is
prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.

Table of Contents

Questions and Answers

  • L
    Laura HoffmanAug 18, 2025
    Why is there poor vacuum in my multivac P100 pack?
    • T
      Theresa MedinaAug 18, 2025
      A poor vacuum in the pack can occur due to several reasons. The evacuation time may be set incorrectly, so try increasing it. Ensure the pouch neck isn't clamped by the chamber lid; reposition the film pouch so the neck is within the chamber, cutting it off if needed. A dirty chamber lid gasket can also cause this, so clean it. Check the oil level and quality in the vacuum pump; refill or replace the oil if needed. Also, a damaged chamber lid gasket can be the cause, so replace it. If you are using moist or liquid products, steam might be interfering with the evacuation process, in which case you should abort the process if the chamber lid mists up. If none of these steps help, the evacuation system may be leaking, and you should notify the service.
  • N
    nathan50Aug 20, 2025
    What to do if the multivac P100 Kitchen Appliances pack is leaking?
    • D
      dominic53Aug 21, 2025
      If your pack is leaking, it could be due to several reasons. First, try increasing the sealing time in small increments. Ensure that the pouch neck is not clamped by the chamber lid; if it is, insert the film pouch so that the pouch neck lies within the chamber, and cut off the pouch neck if necessary. Also, a dirty seal seam can cause leaks, so keep the inside of the film pouch in the area of the seal seam clean. Finally, the film pouch itself might be damaged, so try using a new film pouch.
  • L
    Laura RobinsonAug 23, 2025
    What to do if Multivac Kitchen Appliances chamber lid does not stay closed?
    • S
      Scott HardyAug 23, 2025
      If the chamber lid of your appliance isn't staying closed despite the pump running, ensure you are pressing the chamber lid shut evenly, firmly, and for a sufficient duration. Also, a dirty chamber lid gasket can prevent proper sealing, so clean it. If the gasket is damaged, it will need to be replaced.
  • C
    Craig DudleyAug 26, 2025
    How to fix uneven seal seam of Multivac Kitchen Appliances?
    • S
      Suzanne SwansonAug 26, 2025
      An uneven and wavy seal seam can occur if the pressure difference between the chamber and the outside environment isn't large enough before sealing; set the evacuation time to achieve at least a 0.35 bar pressure difference. Worn Teflon tapes on the sealing bar and counter-pressure bar can also cause this, so replace the Teflon tapes. If the profile thread in the counter-pressure bar is worn, it needs to be repaired.
  • J
    justincurtisAug 27, 2025
    What to do if my multivac P100 Kitchen Appliances machine does not run?
    • W
      Wendy GainesAug 27, 2025
      If your machine isn't running, first, ensure that the machine is switched on. If it is, check that the mains plug is properly plugged in.
  • P
    Peter GarciaAug 30, 2025
    What to do if the chamber lid of multivac P100 Kitchen Appliances does not open?
    • W
      William RobertsAug 30, 2025
      If the chamber lid doesn't open after packaging, first check if the gas strut is un-hooked. If so, hook in the gas strut by opening the chamber lid more than half way. If this doesn't solve the issue, the ventilation valve may not be opening, or the machine control may be defective. In either of these cases, you should notify the service.
  • M
    Melissa MurphySep 1, 2025
    Why does the vacuum pump only run briefly on my multivac P100?
    • N
      nathandelgadoSep 1, 2025
      If the vacuum pump is only running for a short period, the evacuation time might be set incorrectly. Try increasing the evacuation time.
  • C
    Cheyenne MackSep 3, 2025
    Why is the seal seam milky on my Multivac Kitchen Appliances?
    • K
      Kenneth KingSep 3, 2025
      A milky seal seam indicates that the sealing time is set incorrectly. Reduce the sealing time until the seal seam is clear and transparent.
  • K
    Kathleen HancockSep 5, 2025
    Why does the chamber lid open during sealing on my multivac P100?
    • R
      Ryan AndersonSep 6, 2025
      If the chamber lid opens during the sealing process, it's likely due to an insufficient pressure difference between the chamber and the outside environment. Set the evacuation time such that the pressure display shows a pressure difference of at least 0.35 bar before starting the sealing process.
  • J
    Jorge CoxSep 8, 2025
    Why is my multivac P100 Kitchen Appliances machine so loud?
    • J
      Joseph DeanSep 8, 2025
      If your machine is very loud, it could be due to a clogged air de-oiling element, in which case you should change it. Alternatively, the vacuum pump may be defective, requiring you to notify the service.

Summary

Important Information on the Manual

Machine Documentation

Outlines the available documentation, including the instruction manual and EU Declaration of Conformity.

Symbols Used

Explains the meaning of various warning symbols and informational icons found in the manual.

Safety

General Safety Instructions

Covers fundamental safety principles, reading the manual, and adhering to regulations for safe operation.

Operating Company Obligations

Details the responsibilities of the operating company, including creating directives and monitoring machine status.

Danger Zones and Specific Hazards

Highlights hazards in areas like the chamber lid, vacuum pump, and electrical system, with required precautions.

Pack Checking and Hygiene Risks

Emphasizes health hazards from faulty packs and the importance of hygiene during operation.

Description

Machine Construction Overview

Provides an overview and identifies key components of the machine's construction.

Control Terminal and Display Functions

Details the control terminal keys, displays, and their operational meanings.

Process Sequence and Setting Times

Explains the automatic process sequence and how to set evacuation and sealing times.

Technical Specifications

Lists technical data including power supply, dimensions, and environmental conditions.

Start-up

Machine Setup and Initial Operation

Guides on preparing a level site, ensuring space, and connecting power for machine setup.

Operation

Chamber Lid Operation and Machine Power

Instructions for opening/closing the lid and switching the machine on/off.

Setting Times and Packing Products

How to adjust operational times and the step-by-step process for packing products.

Process Control: Aborting, Recipes, Pump Protection

Procedures for aborting processes, managing recipes, and pump protection functions.

Adjustment Work and Setup

Sloping Insert Installation and Use

Guide on inserting and removing the sloping insert for packaging liquids.

Cleaning

Cleaning Guidelines and Machine Value

Obligation to create guidelines and the importance of proper cleaning for machine longevity.

Handling Cleaning Agents and Devices

Safety instructions for cleansers, disinfectants, lubricants, and cleaning equipment.

Cleaning Recommendations and Procedures

General recommendations and detailed steps for cleaning the machine and its components.

Maintenance

Maintenance Schedule Overview

Provides a schedule for required maintenance tasks based on operating hours or time intervals.

Service Recommendations: Visual Inspection

Details visual checks for the entire machine, connections, and safety devices.

Service Recommendations: Vacuum Pump

Specific maintenance tasks for the vacuum pump, including oil checks and changes.

Service Recommendations: Component Replacement

Covers replacement and repair of sealing bars, counter-pressure bars, housing, and gaskets.

Troubleshooting

Faults with Diagnostic Messages

Lists common errors with diagnostic codes, their causes, and solutions.

Faults Without Diagnostic Messages

Lists common issues without codes, their causes, and solutions.

Shutdown, Transport, and Storage

Machine Shutdown and Transport Procedures

Steps for safely shutting down, and precautions for transporting the heavy machine.

Storage Guidelines

Instructions for selecting a suitable storage site and observing ambient conditions.

Disposal

Machine and Operating Materials Disposal

Procedures for safe and environmentally sound disposal of the machine, oil, grease, and chemicals.

Spare Parts

MULTIVAC Branch Offices

multivac P100 Specifications

General IconGeneral
TypeVacuum Sealer
ModelP100
CategoryKitchen Appliances
Sealing MethodHeat Sealing
Sealing Width3 mm
Frequency60 Hz