Description
Technical specifications
11.06.2014 29
Noise exposure at the workplace
Based on Machinery Directive
(2006/42/EC)
Measuring instrument Sound level meter, IEC 61672- 1,
class 1, fault limit +/-1,1 dB
Condition of the machine New condition with optimum set-
tings at the time of delivery.
A-weighted emission sound-
pressure level at the workplace
L
pA
(DIN ISO 11204, accuracy
class 3)
<70 dB
0,5 m
1,55 m
0,7 m
A
A
Fig. 13: Noise exposure measuring point
Info
The measured values of the noise data have been adjusted to take
extraneous and ambient noises into account.
Higher measured values may be produced as a result of the follow-
ing:
• Highly sound-reflecting rooms.
• Modified settings.
• Wear.