EasyManua.ls Logo

multivac P100 - Page 29

multivac P100
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description
Technical specifications
11.06.2014 29
Noise exposure at the workplace
Based on Machinery Directive
(2006/42/EC)
Measuring instrument Sound level meter, IEC 61672- 1,
class 1, fault limit +/-1,1 dB
Condition of the machine New condition with optimum set-
tings at the time of delivery.
A-weighted emission sound-
pressure level at the workplace
L
pA
(DIN ISO 11204, accuracy
class 3)
<70 dB
0,5 m
1,55 m
0,7 m
A
A
Fig. 13: Noise exposure measuring point
Info
The measured values of the noise data have been adjusted to take
extraneous and ambient noises into account.
Higher measured values may be produced as a result of the follow-
ing:
Highly sound-reflecting rooms.
• Modified settings.
• Wear.