Section 40 00-02-0994
2016-06-28 - 45 -
REGISTER #
TYPE
DESCRIPTION
#8
Oil Filter Restriction Warn Status: (1) yes (0) no
#9
Low Engine Temperature Warn Status: (1) yes (0) no
#10
High Engine Oil Pressure Warn Status: (1) yes (0) no
#11
Battery Charger Fail Warn Status: (1) yes (0) no
#12
Run To Destruct Warn Status: (1) yes (0) no
#13
Battery High Warn Status: (1) yes (0) no
#14
Battery Low Warn Status: (1) yes (0) no
#15
Amber Lamp Status: (1) yes (0) no
Slave Address: the Modbus Slave device address.
Serial Setup:
Baud Rate
9600
19200
38400
57600
115200
Stop Bits
0
1
2
Parity
None
Odd
Even
PV CAN Backlight Enable
Off
On
CAN Termination
Enable
Disable
PC Configuration Software
The MPC-20 controller is the first engine controller released utilizing Murphy’s PowerVision Configuration Studio
®
software. With PowerVision, engineering will be able to deliver quicker software updates with the flexibility of a
software developer’s environment. The new addition of PowerVision to this controller gives Enovation Controls the
ability to provide a free-of-charge basic PC configuration program to change default parameters in the controller to
all customers.
The simplified version of PowerVision that will be utilized to create the configuration for the MPC-20 Controller will
be available via download from our website (Forum).
http://forum.fwmurphy.com/viewforum.php?f=49
Customers who require a developer’s environment to change or add additional functionality in the controller may
do so in their own time without waiting or paying non-recurring engineering fees (also referred to as NRE) to make
the changes (requires purchase of full version of PowerVision Configuration Studio
®
).