9 Troubleshooting RJ-901C/RJ-900C   Maintenance Manual
9-20
7 E 016 error
CPU Err
[06]
Address
exception error
(command
fetch):
Address error
in command
loading or
storing
3. Check serial
number of the
plotter.
4. Main board
assembly may be
defective.
•Contact our
customer support
center.
• Replace main board
assembly.
"4.3.3
Replacing
Main Board
Assembly"
p.4-21
8 E 016 error
CPU Err
[07]
Bus exception
error (load or
store):
Bus error in
command
loading or
storing
1. Check serial
number of the
plotter.
2. Main board
assembly may be
defective.
•Contact our
customer support
center.
• Replace main board
assembly.
"4.3.3
Replacing
Main Board
Assembly"
p.4-21
9 E 016 error
CPU Err
[08]
System call
exception
error:
Abnormal
condition in
system call
10 E 016 error
CPU Err
[09]
Break point
exception
error:
Abnormal
condition in
break point
11 E 016 error
CPU Err
[10]
Reserved
command
exception
error:
Abnormal
condition in
reserved
command
12 E 016 error
CPU Err
[11]
Coprocessor
disabled
exception
error:
Abnormal
condition in
coprocessor
Table 9-6 Symptoms and Check Items for CPU System Serious Errors(Continued)
No. Message Event/
symptom
Check item Action Reference