7 Disposal of waste fluids
(1) Disposal timing
Dispose of waste fluids in the following cases:
When the waste fluid tank is more than half full.
When “Waste Ink Tank Full” is displayed
(2) Disposal method
Step 1: Please have an empty container such as a supply waste fluid bottle, to contain the
waste fluid.
Step 2: Put some protective material on the floor under the waste fluid tank.
Step 3: Open the waste fluid tap, and transfer the waste fluid to the container.
When transferring the waste fluid to the empty container, the waste fluid may
spatter.
Make sure to put the container close to the waste fluid tap.
Step 4: Af
ter p
ouring the waste fluid to the empty container, close the waste fluid tap securely.
Step 5: Wipe the opening of the waste fluid tap with a cloth, etc.
Step 6: Dispose of the waste fluid as an industrial waste product.
Disposal of waste fluids is completed.
Important
Please dispose according to local rules and regulations. For details, please
verify the corresponding safety data sheet MSDS on the Mutoh website.
Disposal can be found in section 13 of the SDS.
No. Name
1 Waste fluid tap
2 E
mpty container

Other manuals for MUTOH valuejet 1614

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MUTOH valuejet 1614 and is the answer not in the manual?

MUTOH valuejet 1614 Specifications

General IconGeneral
BrandMUTOH
Modelvaluejet 1614
CategoryPrinter
LanguageEnglish

Related product manuals