7
Gas Category
I
3B/P(30)
I
3+(28-30/37)
I
3B/P(50)
Orice Sizes(see above) I I II
Gases / Pressures Butane and Propane
at 30mbar
Butane 28-30mbar
Propane 37mbar
Butane and Propane
at 50mbar
Countries BE, BG, CY, DK, EE, FI,
FR, GB, HR, HU, IS, IT,
LT, LU, MT, NL, NO,
RO, SE, SI, SK, TR
BE, CH, CY, CZ, ES, FR,
GB, GR, IE, IT, LT, LU,
LV, PT, SK, SI
AT, CH, DE, SK
WARNING!
• Do not route hose underneath drip pan.
• Ensure all connecons are ghtened using two wrenches. Do not use Teon tape or pipe dope on
any hose connecon.
• Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing a
re.
Gas Hose
• If the hose and regulator are not included by the manufacturer, then only hoses and regulators which
meet naonal and regional codes are to be used.
• Ensure that the hose does not come into contact with grease, other hot drippings, or any hot surfaces
on the appliance.
• Check hose regularly. In the case of rips, melng or wear, replace hose before using the appliance.
• The hose must not be longer than 1.5m.
• Ensure that the hose is twist and kink free when installed.
• Replace the hose before expiry date printed on the hose.
Technical Data
The following table lists input values for the appliance.
Burner Orice Size (Gross) Heat Input (Total) Gas Usage (Total)
I II I II I II
#69 (0.74 mm) #73 (0.61 mm) 4.1kW 4.1kW 301 g/hr 301 g/hr
Cered Gases / Pressures - Check rang plate to ensure that it corresponds with following list.
Do not tamper with or modify regulator. Use only regulators which supply the pressure listed in the table
above. For replacement, use only the regulator specied by the manufacturer.