Safety Voltages
Connect only voltages that are below these limits.
V terminal to C terminal 30 VDC maximum, Measurement Category I
Preparing the Environment
Ensure that the environment in which you are using the sbRIO-9607 meets the
following specifications.
Local ambient operating temperature near
device (IEC 60068-2-1, IEC 60068-2-2)
-40 °C to 85 °C
Maximum reported onboard sensor temperature
CPU/FPGA temperature 98 °C
Primary System temperature 85 °C
Secondary System temperature 85 °C
Note Ensure that the local ambient, reported CPU/FPGA, and reported
Primary System temperatures do not exceed any of the maximum
temperatures listed in this document. For more information about how to
access the onboard sensors, visit ni.com/info and enter the Info Code
sbriosensors.
Operating humidity (IEC 60068-2-78) 10% RH to 90% RH, noncondensing
Pollution Degree (IEC 60664) 2
Maximum altitude 5,000 m
Indoor use only.
Note Refer to the device specifications on ni.com/manuals for complete
specifications.