10. Click Finish when the installation is complete.
Troubleshooting the sbRIO-9607
The sbRIO-9607 is Not Communicating with the Network
■
Ensure that the Ethernet connections between the sbRIO-9607 and the host
computer and the Ethernet connections between the host computer and the
router are secure.
■
Ensure that you have the correct version of NI CompactRIO Device Drivers
installed on the host computer. Visit
ni.com/info and enter the Info Code
sowareversion for the minimum supported versions of LabVIEW and NI
CompactRIO Device Drivers.
Tip If you have recently upgraded LabVIEW, you must reinstall NI
CompactRIO Device Drivers.
■
Temporarily disable any network firewalls or other security soware.
Configure the IP and other network settings by completing the following steps.
1.
Use a standard Category 5 (CAT-5) or better shielded, twisted-pair Ethernet
cable to connect the sbRIO-9607 Ethernet port to a host computer. The
sbRIO-9607 attempts to initiate a DHCP network connection at powerup.
2. In MAX, expand your system under Remote Systems and select Troubleshoot
Remote System Discovery.
System Reset
The following figure shows the reset behavior of the sbRIO-9607.
© National Instruments
11
sbRIO-9607 Getting Started