VX150 TO VX2 INSTALLATION MANUAL CONTROL AND MONITOR WIRING
VERSION 0.3 2021-01-14 PAGE 1.8.1
SECTION 1.8: CONTROL AND MONITOR WIRING
This section describes the types of control and monitoring for the VX150 to VX2 transmitter. All
connections are made to the rear panel of the transmitter (see Figure 1.7.1: on page 1.7.5). Consider the
following information and plan for the necessary requirements (wiring, remote switches/ indicators,
LAN, etc.):
Front Panel UI Control
Remote Inputs - see page 1.8.2
Remote Outputs - see page 1.8.4
Analog Outputs - see page 1.8.6
Web Based AUI Control - see page 1.8.7
SNMP Control/Monitoring - see page 1.8.8
External Interlock - see page 1.8.9
NOTE:
This section provides the information required to determine your control and monitor wiring and
plan for their connection to the transmitter. Physical connections are made in
Section 1.10, “Completing
External Connections” on page 10-1
.
Front Panel UI Control
The VX1’s front panel user-interface (UI) lets you locally control a number of transmitter functions and
set parameters.
For detailed information about the front panel UI, refer to the VX Operating and Maintenance Manual.
In addition, the front panel UI lets you define and control the on/off status, the preset RF power level,
and the system alarm reset remotely using a conventional remote control interface (see Remote Inputs -
see page 1.8.2 and Remote Outputs - see page 1.8.4) or a LAN (see Web Based AUI Control - see
page 1.8.7.