VX150 TO VX2 INSTALLATION MANUAL CONTROL AND MONITOR WIRING
VERSION 0.3 2021-01-14 PAGE 1.8.9
Email Server
The transmitter’s remote AUI allows you to configure an email notification feature, which can initiate
emails to specified users when specific alarm or status conditions occur (refer to the VX
Operations and
Maintenance Manual
for details).
The VX series transmitter supports email servers that are both unsecure and secure; requiring
authentication (user name/password) as well as encryption. Consult with your network administrator
for more details.
External Interlock
An external safety interlock is available on the INTLK terminal block on the rear panel of the
transmitter. This connection allows you to connect an external safety interlock circuit that provides an
emergency RF inhibit control for the VX transmitter. It must present a short circuit (low impedance)
between the terminals when the interlock circuit is intact and it is safe to enable the RF output. It must
present an open circuit when any interlock switch is activated and the RF output should be inhibited. A
mating connector (Nautel part # JR52) is supplied in the ancillary kit to facilitate this connection.