Installation Guide
Pelvac Vacuum Transport System with rotary valves
SKU: 708100, 707100
Under Vacuum Transport Menu:
1. Specify Outputs for Vacuum/Rotary valve and
External(Extraction )Auger in the controller
2. Specify Maximum Distance (i.e. distance from the
sensor when the vacuum will start) and Minimum
Distance (i.e distance from the sensor when the
vacuum should stop) .
Vacuum Transport Menu :
External Feed Auger Output: Select the output the auger is connected to
Vacuum Output: Select the output the vacuum is connected to
Duty Cycle %: Running time in percent for external feed auger. 100% = Always on.
Minutes per cm min: Maximum minutes allowed for at least one centimeter increase of pellets in hopper.
Distance sensor alarm time min: Amount of time the distance sensor is out of range before triggering an alarm
Minimum Distance cm: Distance used to stop the external feed system
Maximum Distance: Distance used to start the external feed system
Schedule: Select time periods when the vacuum transport system is allowed to run
Running Time Hours: The total amount of hours that the vacuum transport system has been running