Getting Started
How To Open and Close The Electronic Dial Combination Lock
NCR
SHUVRQD
V
ATM Operator Manual 2-17
How To Open and Close The
Electronic Dial Combination
Lock
2
Unlocking
2
To open the security enclosure proceed as follows:
Note:
If when entering a combination you enter the
wrong combination 4 times a 5 minute time delay period
is activated. During this time the led on the lock will
flash red at 10 second intervals. You must wait until the
end of the 5 minute period before attempting to enter the
correct combination.
Note:
If fitted, the silent alarm may be activated by
entering one number higher or lower for the last digit of
a combination. For example if the combination was 1-2-
3-4-5-6, entering 1-2-3-4-5-5 or 1-2-3-4-5-7 would activate
the silent alarm.
Note:
Repeated beeping of the lock during an opening
sequence indicates that the lock battery requires
replacing. If the lock keypad is completely “dead”, that is
it makes no sound or flashes, follow the emergency
opening procedure to open the lock prior to having the
battery replaced.
Book.bk Page 17 Thursday, March 11, 1999 2:24 PM