1. IML Error Message
Express5800/R120h-1E, R120h-2E Maintenance Guide
182
Chapter 3 Appendix
Class
Error
code
Error message Action
Environment 24
External Chassis Fans Not Redundant
(Chassis %1, Location %2)
Contact your sales representative.
Environment 25
%1 Storage System Fans Not Redundant
(%2Slot %3, Location %4)
Contact your sales representative.
Environment 26 %1 Fans Not Redundant (Location %2, %3) Contact your sales representative.
Environment 27 Critical Temperature Threshold Exceeded
Check the ambient temperature where the unit
is being operated.
If the problem persists, contact your sales
representative.
Environment 28
Critical Temperature Threshold Exceeded
(Temperature Sensor %1, Location %2,
Temperature %3C %4)
Check the ambient temperature where the unit
is being operated.
If the problem persists, contact your sales
representative.
Environment 29
External Chassis Overheating (Chassis %1,
Temperature Sensor %2, Location %3,
Temperature %4)
Check the ambient temperature where the
expansion chassis connected to the unit is
being operated.
If the problem persists, contact your sales
representative.
Environment 2A
%1 Storage System Overheating (%2Slot %3,
Temperature Sensor %4, Location %5,
Temperature %6)
Check the ambient temperature where the %1
connected to the unit is being operated.
If the problem persists, contact your sales
representative.
Environment 2B
%1 Overheating (Temperature Sensor %2,
Location %3, Temperature %4, %5)
Check the ambient temperature where the %1
connected to the unit is being operated.
If the problem persists, contact your sales
representative.
Environment 2C Temperature exceeded on PCIe disk %1. Contact your sales representative.
Environment 2D Intrusion Alert Hardware installed.
No additional action is required, if the applicable
HW has been added.
If the problem persists, contact your sales
representative.
Environment 2E
#ILO had detected the removal of the Intrusion
Alert hardware.
No additional action is required, if the applicable
HW has been removed.
If the problem persists, contact your sales
representative.
Environment 2F
Intrusion Alert Detection - The server chassis hood
is currently not installed.
The cover of the unit has been removed. Please
attach the cover.
If it is not a record of the intended operation, the
security of the unit may have been
compromised. Please take an appropriate
measure.
If the problem persists, contact your sales
representative.
Environment 30 The chassis hood has been replaced.
It detected that the cover of the unit has been
removed.
If it is not a record of the intended operation, the
security of the unit may have been
compromised. Please take an appropriate
measure.
If the problem persists, contact your sales
representative.
Environment 31
%1 Storage Enclosure Fan Failure (Fan %2,
Location %3, Box %4, %5)
Contact your sales representative.
Environment 32
%1 Storage Enclosure Overheating (Temperature
Sensor %2, Location %3, Box %4, %5)
Contact your sales representative.
Environment 33 Fan Degraded (Fan %1, Location %2) Contact your sales representative.