English−16
Changing handles position
: Factory set position.
: Alternate position.
CAUTION: Four or more handles are required when transporting.
(Recommended Fasten Force: 139 - 189 N•cm)
C750Q C860Q
Ventilation Requirements
When mounting in an enclosed space or recessed area, leave adequate room between the monitor and the enclosure to allow
heat to disperse, as shown below.
100 mm
100 mm
30 mm
100 mm
100 mm
Must be under 40 Degree Celsius.
NOTE: • Allow adequate ventilation or provide air conditioning around the monitor, so that heat can properly dissipate away
from the unit and the mounting equipment; especially when you use monitors in a multiple screen configuration.
• This monitor has internal temperature sensors.
If the monitor overheats, a “Caution” warning appears. If the “Caution” warning appears, stop using the unit, turn off
the power and allow it to cool.
If the monitor is used in an enclosed area or if the LCD panel is covered with a protective screen, and the
temperature is higher than the normal operating temperature, please turn the cooling fan to [ON] within the
[FAN CONTROL] menu within the OSD (see page 82).
Mounting on Ceilings
WARNING: Please refer to “WARNING 8” and “WARNING 9”.