ND-45383 (E) CHAPTER 3
Page 83
Revision CD 1.0
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Note 5: Switch setting for bit rate of D
term
Data Port
SW10-3. SW10-4.
(for No. 0 DLI)/ (for No. 0 DLI)/
SW20-3. SW20-4.
(for No. 1 DLI)/ (for No. 1 DLI)/
For DRU-30-S3
64 K (Standard Setting) : OFF OFF
64 K INV : ON OFF
56 K : OFF ON
48 K : ON ON
For DRU-30-A : OFF OFF
Note 6: Switch setting for designating the case where simultaneous communications of voice and APA/APR (Analog
Port Adapter) are performed or the case where the Data Adapter is used. *
SW13-2/SW23-2: for No. 0 ~ 3 circuit
SW13-3/SW23-3: for No. 4 ~ 7 circuit
SW13-4/SW23-4: for No. 8 ~ 14 circuit
SW13-2/13-3/13-4 (for No. 0 DLI)
SW23-2/23-3/23-4 (for No. 1 DLI)
When simultaneous communications of voice and APA/APR ON
(Analog Port Adapter) are performed.
(In this case, the Data Adapter cannot be used.)
When the Data Adapter is used. OFF
*This switch setting is effective when using DRU-30-S3 by 15DLC mode. When the type of the DRU is DRU-
30-A or when DRU-30-S3 is used by 30ELC mode, set these switches to OFF.
SYMBOL CIRCUIT CARD
2DLI PA-2DAID