Installation Guide
QX-S5500G Series Ethernet Switches
6. Upgrading software
6-40
9 5981 flash:/startup.cfg_back
10(*) 6098 flash:/startup.cfg
11 20 flash:/.snmpboots
Free space: 464298848 bytes
The current image is boot.bin
(*)-with main attribute
(b)-with backup attribute
(*b)-with both main and backup attribute
2) Enter the number of the file to delete. For example, enter 1 to select the file
testbackup.cfg.
Please input the file number to change: 1
3) Enter Y at the confirmation prompt.
The file you selected is testbackup.cfg,Delete it? (Y/N):Y
Deleting....................................Done!
III. Changing the attribute of software images
Software image attributes include main (M), backup (B), and none (N). System software
and boot software can each have multiple none-attribute images but only one main image
and one backup image on the switch. You can assign both the M and B attributes to one
image. If the M or B attribute you are assigning has been assigned to another image, the
assignment removes the attribute from that image. If the removed attribute is the sole
attribute of the image, its attribute changes to N.
For example, the system image system.bin has the M attribute and the system image
system-update.bin has the B attribute. After you assign the M attribute to
system-update.bin, the attribute of system-update.bin changes to M+B and the attribute
of system.bin changes to N.
To change the attribute of a system or boot image:
1) Enter 2 in the Boot menu.
EXTENDED BOOT MENU
1. Download image to flash
2. Select image to boot
3. Display all files in flash
4. Delete file from flash
5. Restore to factory default configuration

Table of Contents