Installation and Configuration | AEOS Blue and vehicle identification EN
Manual version 3 42/48
4. Enter the correct settings, as shown in the table below.
Property
Value
SERIAL ACTION ENABLE
ON
BAUD RATE
9600
MESSAGE
%LP%%CR%
5. Click SAVE.
6.2 Configuring AEmon
To connect an ANPR LUMO camera to AEOS via RS485, use an AP7031 AEOS Blue door interface in
combination with the Generic Message Mapper AEbc. To configure the AEOS Blue door interface
for the ANPR LUMO reader in AEmon, take the following steps:
Configure the identifier type in AEmon
1. Start AEmon
2. In AEmon, create/open the configuration, including the AP7031 AEOS Blue door interface,
the Generic Message Mapper AEbc, the LabelValueToString AEbc, the StringFormatter
AEbc, the InputToBadge AEbc and the StandardDoor access point (see the AEOS Access
Points and Entrances manual).
3. Right-click the
Generic Message Mapper AEbc and click Properties.