WARNING! Risk of personal injury.
• Ensure that there is no vacuum present in the system during service.
• Always disconnect the compressed air supply before any service.
NOTE! Check all power conductors and protecve conductors one month aer installaon
and ghten, if required, to ensure good contact. Service to the electrical equipment may
only be carried out by a qualied electrician.
One month aer installaon, and then every year, perform the following checks:
• Check all power and protecve conductors and ground wire connecons. Tighten, if
required, to ensure good contact.
• Inspect the integrity of the dust separator.
• Ensure that the inside of the unit and the connecon ducts are free from deposits.
Build-up of deposits inside the duct system may cause discharge of stac electricity.
• Clean the area around the unit and all areas where the collected material is stored to
ensure that there are no dust deposits.
• Check that all signs/markings regarding safe operaon are in place and that the
personnel knows about them.
6.2 Empty the collector bin
WARNING! Risk of personal injury.
• Ensure that there is no vacuum in the dust separator before removing the collector bin.
• Crush hazard. Be careful when lowering and reng the collector bin. Use proper
protecve equipment.
• Wear goggles, dust mask and gloves when emptying the collector bin.
NOTE! The plasc bag is to be replaced when lled up to 2/3, see gure 11.
Do the following to replace the plasc bag:
1. Ensure that there is no vacuum in the dust separator.
2. Remove the collector bin.
3. Seal and remove the plasc bag. Use a cable e or equivalent, see gure 12.
4. Fit a new plasc bag in the collector bin.
5. Ret the collector bin onto the dust separator.
6. Check that the pressure equalizer hose is aached to the collector bin, see gure 14.
7. Check that the collector bin seals properly once vacuum is re-applied to the dust
separator.
6.3 Replace main lter
NOTE! Fing the steel ring correctly is important to maintain the ghtness and durability
of the unit. Do not forget to reground it.
Filter replacement is to be noted in the service protocol of the unit. Replacing individual
lter bags is possible, but it is recommended that the whole lter package is replaced since
it is quicker and causes less spreading of dust. The work is easy, if the unit is placed so it
can be lted, see gure 15. Also, the lter may be lied straight up, see gure 16, with a
crane or other liing device.
If the lter bags are replaced separately, the plasc holders will also have to be replaced.