FlexPAK 800/1000
23
EN
Figure 17, items A–C, shows how the rubber sealing rings are to be ed. When a used
sealing ring is to be re-used, the form when open may dier from the original form as
shown in item A. Use a screwdriver to bring the edge of the module between the rubber
lips to obtain the result shown in item C.
6.4 Check the lter cleaning funcon
WARNING! Risk of personal injury.
Crush hazard. Pay aenon when the compressed air pressure cylinder and valve disc
move. Make sure that the protecon hood over the lter cleaning unit is ed aer the
check.
Check the automac lter cleaning as follows:
1. Check the automac cleaning equipment once a year.
2. Remove the top cover from the lter and inspect the valve disc.
3. Start the unit and press the lter cleaning buon, see gure 8. The compressed air
cylinder should li the valve disc. A loud noise can be heard as air rushes into the
lter bin to blow o dust from the outside of the lter package. This will be repeated
3 mes for each lter cleaning cycle.
4. Stop the vacuum unit and shut o the air supply.
5. Check the valve disc fastening, damage and wear. Replace if required.
6. Replace the protecng top cover.
6.5 The motor and the fan unit
Inspect and clean the motor compartment regularly.
The motor has 2 ball bearings. The bearings are to be replaced aer approximately
15,000 hours of operaon. If the ambient temperature oen reaches 35°C (95°F), the me
between replacements is to be reduced. In any case, the bearings are to be replaced every
h year.
The bearings are a standard type. Contact Nederman or an authorized Nederman
distributor for replacement of the bearings.
Old grease is to be removed and new grease used. The grease is to meet the DIN 51825-
K2N 40, SKF LGHP 2 or FAG Arcanol Multop standards.
6.6 Cooling lter for the frequency converter
The service life of the cooling lter for the frequency converter depends on the air-bound
dust surrounding the vacuum unit. The expected service life is 6–48 months. Check the
lter regularly through the lter holder grid. If the lter is clogged, the frequency converter
will shut o due to overheang. When changing the lter, see the label placed over the
lter intake.
6.7 Loading new soware
NOTE! This secon is only for Nederman qualied service technicians.
NOTE! Make notes of actual parameter sengs.