Fault
Possible causes
Action
Pos: 26.15.18 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Drehstrommotor wird im Dauerbetrieb zu war m @ 30\mod_1517997892579_2901.docx @ 278461 @ @ 1
6 3-phase AC motor becomes
too warm in continuous
operation
• Load too high
➔ Measure power input*
• Voltage too high or too low
➔ Check main voltage and voltage drop up to
electric drive*
• Single-phase instead of 3-
phase operation
➔ Check power input of all three lines*
• Short circuit in coil
➔ Check supply line for interruption and, if
necessary, eliminate or have rewound
• Ventilation impaired
➔ Remove dust, chips or the like from air paths
➔ Re-adjust air deflectors
➔ Prevent intake of warm exhaust air
• Rotor grinds in stator
➔ Adjust or replace bearings
• Foreign matter in air gap
➔ Dismantle rotor and clean motor
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzungslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1
Pos: 26.15.20 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Stoßartiger Anlauf @ 30\mod_1 5180084 66527_2901.docx @ 278509 @ @ 1
7 Jerky start
• Short circuit in the rotor winding
➔ Eliminate short circuit or have rewound
• Connection to PEN conductor
instead of to outer conductor
➔ Check connections and, if necessary, correct
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzungslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1
Pos: 26.15.22 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Mit doppelter Schlupffrequenz schwanken de Stromaufnahmen @ 30\mod_15 18009369427_2901.docx @ 27853 7 @ @ 1
8 Power input fluctuating with
double slip frequency
• Interruption in winding or
asymmetry of resistances in
rotor or defective short-circuiter
➔ Measure resistances
➔ Have motor repaired by qualified staff
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzun gslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1
Pos: 26.15.24 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Drehstrommotor läuft in Stern- Dreieck- Schaltung @ 30\mod_1518009844630_2901.docx @ 27856 5 @ @ 1
9 3-phase AC motor runs too
slowly or not at all in star
delta connection high
• Load too high
➔ Relieve load of fan*
• Terminal voltage too high
➔ Check main voltage on activation
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzun gslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1
Pos: 26.15.26 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Falsche Drehrichtung @ 30\mod_1518011481581_2901.docx @ 278593 @ @ 1
10 Wrong direction of rotation
• Motor disconnected
➔ Two phases interchanged
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzun gslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1
Pos: 26.15.28 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Drehstrommotor zeigt zu hohen Leerlaufstro m @ 30\mod_1518012050493_2901.docx @ 278621 @ @ 1
11 3-phase AC motor shows
excessive no load current
• Terminal voltage too high
➔ Measure main voltage*
• Air gap possibly increased
during repairs
➔ Measure air gap at three points and, if
necessary, set correctly
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzungslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1
Pos: 27 /Betriebs anleitung/----- Seitenumbruch ----- @ 10\mod_1478587717206_0.docx @ 209487 @ @ 1

Table of Contents