60
Pos: 26.15.17 /Betriebsanleitung/12 Störungsbehebung/TABELLE: Titelzeile Checkliste Störungen @ 20\mod_ 1492002750700_2901.docx @ 231449 @ @ 1
Fault
Possible causes
Action
Pos: 26.15.18 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Drehstrommotor wird im Dauerbetrieb zu war m @ 30\mod_1517997892579_2901.docx @ 278461 @ @ 1
6 3-phase AC motor becomes
too warm in continuous
operation
Load too high
Measure power input*
Voltage too high or too low
Check main voltage and voltage drop up to
electric drive*
Single-phase instead of 3-
phase operation
Check power input of all three lines*
Short circuit in coil
Check supply line for interruption and, if
necessary, eliminate or have rewound
Ventilation impaired
Remove dust, chips or the like from air paths
Re-adjust air deflectors
Prevent intake of warm exhaust air
Rotor grinds in stator
Adjust or replace bearings
Foreign matter in air gap
Dismantle rotor and clean motor
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzungslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1
Pos: 26.15.20 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Stoßartiger Anlauf @ 30\mod_1 5180084 66527_2901.docx @ 278509 @ @ 1
7 Jerky start
Short circuit in the rotor winding
Eliminate short circuit or have rewound
Connection to PEN conductor
instead of to outer conductor
Check connections and, if necessary, correct
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzungslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1
Pos: 26.15.22 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Mit doppelter Schlupffrequenz schwanken de Stromaufnahmen @ 30\mod_15 18009369427_2901.docx @ 27853 7 @ @ 1
8 Power input fluctuating with
double slip frequency
Interruption in winding or
asymmetry of resistances in
rotor or defective short-circuiter
Measure resistances
Have motor repaired by qualified staff
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzun gslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1
Pos: 26.15.24 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Drehstrommotor läuft in Stern- Dreieck- Schaltung @ 30\mod_1518009844630_2901.docx @ 27856 5 @ @ 1
9 3-phase AC motor runs too
slowly or not at all in star
delta connection high
Load too high
Relieve load of fan*
Terminal voltage too high
Check main voltage on activation
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzun gslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1
Pos: 26.15.26 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Falsche Drehrichtung @ 30\mod_1518011481581_2901.docx @ 278593 @ @ 1
10 Wrong direction of rotation
Motor disconnected
Two phases interchanged
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzun gslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1
Pos: 26.15.28 /Betriebsanleitung/12 Störungsbehebung/Elektrische Antriebe/Checkliste: Drehstrommotor zeigt zu hohen Leerlaufstro m @ 30\mod_1518012050493_2901.docx @ 278621 @ @ 1
11 3-phase AC motor shows
excessive no load current
Terminal voltage too high
Measure main voltage*
Air gap possibly increased
during repairs
Measure air gap at three points and, if
necessary, set correctly
Pos: null /Betriebsa nleitung/12 Störungsb ehebung/Begrenzungslinie @ 44\mod_1578479058796_0.docx @ 350427 @ @ 1