EasyManua.ls Logo

Ness AC-1000 - Connection Method Settings; IP Address Settings

Ness AC-1000
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ness AC1000 User Guide
25
VIRDI AC 1000 User Guide 25
UNION COMMUNITY CO.,LTd.
3Fl. Hyundai Topics Bldg, 44-3 Bangi-dong, Songpa-gu, Seoul, Korea 138-050,
Tel: 82-2-6488-3000, Fax: 82-2-6488-3099, E-Mail:sales@unioncomm.co.kr,
- NO mode: select [2]. Even though a user is registered in the terminal,
authentication is done through the server in any event.
Depending on the number of terminals, the number of users, or network
conditions, each different mode can be used flexibly, but if there are more than
10 terminals connected to the server for simultaneous authentication or there
are frequent network problems, it is recommended to use SN authentication
(setting ‘1’).
Press [ENT] to move to the next setting.
3.4.3. Connection method settings
[ENT] Æ [2] Æ [ENT] Æ [ENT]
Network Type:0
0:Static 1:DHCP
Press [0] for Static IP.
Press [1] for DHCP.
The default is ‘0’ (Static IP). If a fixed IP is assigned to the unit in a network,
press [0]. If there is a DHCP server in the network to which the unit is connected,
press [1].
Press [ENT] to move to the next setting.
For Static IP (0), refer to 3.4.4. IP address, 3.4.5. Subnet mask and 3.4.6.
Gateway. For DHCP, skip those sections.
.
3.4.4. IP address settings
< IP Address >
192.168. 0. 3
Press [DEL] to delete an old IP and enter the
new IP.
If the IP address is ‘210.98.100.50’, enter as below:
[2] [1] [0] [9] [8] [ENT] [1] [0] [0] [5] [0]
Press [ENT] to move to the next setting.
.
http://www.unioncomm.co.kr

Table of Contents