Net.DO Lighting Control Equipment Co.,Ltd http://www.netdo.com.cn
FOX512 Moving Light Controller. PAGE: 31
11. Priority Levels of Different Operations
Priority Levels of different operations are as follows:
Manual-Run Fixture
(Priority over) SCENE (Priority over) Playback
Priority between Playbacks:
Priority between Playbacks is according to the rules of HTP and LTP channel mentioned above.
(HTP is “Highest value takes precedence”; LTP is “Latest value takes precedence”.)
Priority between Scenes:
Between Scenes, all channels will be output according to the rule of HTP, which is more
convenient to superimpose scenes.
Priority between SCENE and Playback:
Between SCENE and Playback, HTP channels will be output according to the rule of HTP; LTP
channels will output the value of SCENE. (It means SCENE can superpose on Playback,
playback will restore outputting after SCENE is cancelled.)
Priority of Manual-Run Fixture:
Manual-Run Fixture is of the highest priority, users have to be accustomed to using CLEAR
key to clear the data of Manual-Run, to ensure the output of Playback and SCENE.
12. Software Upgrade
Upgrade file can be obtained from our dealers and company website. Software has to be upgraded
by U-disk.
Steps of upgrade are as follow:
1) Copy the upgrade file to the root directory of U-disk;
2) Turn off the console;
3) Press and hold PROGRAM Key and SETUP Key at the same time, then turn on the console;
Hold the keys until the LCD screen displays “UPDATE PROGRAM ===========”.
4) Press Cursor Key to confirm, then insert U-disk, the console will automatically upgrade.
5) When the upgrade is finished, the console will automatically restart.
(Upgrade will not affect user’s data in the console)