Command: Configure CES Clock Source Priority for a Port
Syntax: ces clock priority port <port> <priority>
Description: Update the clock source priority configuration for a TDM port, where:
<port> : TDM Port Number.
<priority>: Clock Source Priority value (0-19).
Example: Change the TDM Port 1 clock source priority from the default of 19 to 7:
>ces clock priority port 1 7
CES Clock Source Priorities
===========================
Internal: 8
TDM Port 1: 7
Logical Link 1: 19
Logical Link 2: 19
Logical Link 3: 19
Logical Link 4: 19
>
Command: Configure CES Clock Priority for a Stream
Syntax: ces clock priority stream <stream> <priority>
Description: Update the clock source priority configuration for a clock stream (logical link), where:
<stream> : Stream Number (1-4).
<priority>: Clock Source Priority value (0-19).
Example: Change the clock source priority for clock stream (logical link) 1 from the default of 19
to a value or 15:
>ces clock priority stream 1 15
CES Clock Source Priorities
===========================
Internal: 8
TDM Port 1: 7
Logical Link 1: 15
Logical Link 2: 19
Logical Link 3: 19
Logical Link 4: 19
>