EasyManua.ls Logo

Net2Edge PB-TDM1-CONTRA - CES Clock Commands

Default Icon
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Transition Networks Contra Converter Quick Setup Guide
CES Clock Commands
CES clock priority configuration
CES clock priority internal <priority>
CES clock priority port <port> <priority>
CES clock priority stream <stream> <priority>
Command: Display CES Clock Priority Configuration
Syntax: ces clock priority config
Description: Display the current clock source priority configuration.
Example: Display the CES Clock Source Priorities:
>ces clock priority config
CES Clock Source Priorities
===========================
Internal: 0
TDM Port 1: 19
Logical Link 1: 19
Logical Link 2: 19
Logical Link 3: 19
Logical Link 4: 19
>
Command: CES Clock Priority Internal
Syntax: ces clock priority internal <priority>
Description: Update the clock source priority configuration for the internal clock source, where:
<priority>: Clock Source Priority value (0-19).
Example: Change the Clock Source Priority value from the default value of 0 to a priority of 8:
>ces clock priority internal 8
CES Clock Source Priorities
===========================
Internal: 8
TDM Port 1: 19
Logical Link 1: 19
Logical Link 2: 19
Logical Link 3: 19
Logical Link 4: 19
>
33604 Rev. A www.transition.com Page 58 of 72