Transition Networks Contra Converter Quick Setup Guide
CES Clock Commands
CES clock priority configuration
CES clock priority internal <priority>
CES clock priority port <port> <priority>
CES clock priority stream <stream> <priority>
Command: Display CES Clock Priority Configuration
Syntax: ces clock priority config
Description: Display the current clock source priority configuration.
Example: Display the CES Clock Source Priorities:
>ces clock priority config
CES Clock Source Priorities
===========================
Internal: 0
TDM Port 1: 19
Logical Link 1: 19
Logical Link 2: 19
Logical Link 3: 19
Logical Link 4: 19
>
Command: CES Clock Priority Internal
Syntax: ces clock priority internal <priority>
Description: Update the clock source priority configuration for the internal clock source, where:
<priority>: Clock Source Priority value (0-19).
Example: Change the Clock Source Priority value from the default value of 0 to a priority of 8:
>ces clock priority internal 8
CES Clock Source Priorities
===========================
Internal: 8
TDM Port 1: 19
Logical Link 1: 19
Logical Link 2: 19
Logical Link 3: 19
Logical Link 4: 19
>
33604 Rev. A www.transition.com Page 58 of 72