Transition Networks Contra Converter Quick Setup Guide
3. G.703 Port
This setting can be found via the Web GUI in Configuration > CES > Port Settings.
The G.703 Contra port must be configured as either DCE or DTE. DCE mode is Network presentation.
In this mode, Contra Converter’s G.703 port is acting as a Network which a User (DTE) presentation
device will connect to. Clocking is provided from Contra Converter to the DTE device.
DTE mode is User presentation and should be used when Contra Converter is connected to a
Network interface such as a Leased Line. Clocking is provided from the DCE Network into the DTE
Contra Converter.
Select the appropriate Port Type and click Save.
From the CLI, the command to select DTE or DCE mode is:
ces port setup 1 [dce|dte]
33604 Rev. A www.transition.com Page 8 of 72