Netafim nmc-pro - Dosing Configuration; Ec;Ph Control; Ec;Ph Control Alarm Setting

Netafim nmc-pro
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NMC-DC
INSTALLATION MANUAL
Page: of 109 pagesRevision: 01 IDoc. Name: NMC-DC I Installation Manual
Crop Management Technologies
10.5 Dosing Configuration
10.5.2 EC/pH Control- Alarm Setting
Type of each channel configured by
technician during installation process
EC- channel influenced by EC levels
ACID- channel to inject acid to reduce pH levels
PASSIVE- no EC/pH influence
ALKALI- channel to increase pH levels
Ex: If dosing channel 1 is set by the grower to inject 10 liter/m
3
, the controller auto adjust range
is 5 to 15 liter/m
3
in order to meet the EC level.
EC/pH coarse tuning- when way off target, faster/stronger correction
EC/pH fine tuning- off target is low, slow/light correction
Control cycle- Delay time from fertilizer/Acid injection point to EC/pH sensors reading
EC/pH averaging- balanced reading from EC/pH sensors
Dose boost off delay- time clear water circulated through system after fertigation stops and venturi
closes
10.5.1 EC/pH Control- System will inject +/- depending on EC levels, auto-adjust to meet target levels.
Set limits for controller adjustments when levels are too high/low
66