NMC-DC
INSTALLATION MANUAL
Page: of 109 pagesRevision: 01 IDoc. Name: NMC-DC I Installation Manual
Crop Management Technologies
Sensor Type Measured Values Accuracy Input Range
Maximum Cable
Length
Cable Type
Temperature
RTS-s
-20°C to 50°C/ -4°F to
122°F
0.3°C 30kOhm 500 meter (1640 feet)
2x0.5mm²
(20 AWG)
EC
0 to 10mS (old transmitters
used 20mS)
0.05 to 0.1mS 4 20mA ---
3x0.5mm²
(20 AWG)
Sheilded
pH 0 - 14 0.1 4 20mA ---
RH RHS-10 0 100%
±2% (10%-90% RH), ±3.5%
(90%-100% RH)
0 3 VDC 300 meter (985 feet)
3x0.5mm²
(20 AWG)
Pyranometer-
Netafim
300-2800nanometer (Up to
1500W/m²)
±5% 0 5VDC ---
3x0.5mm2
(20AWG)
Shielded
Wind Speed 4-280 km/hr (2-175 mph) ±5%
Pulse output
(Wind Cups &
Magnetic
Switch)
100 meter (330 feet)
4x0.5mm²
(20 AWG)
Pressure Up to 10bar (145 PSI) --- 0 5 VDC ---
3x0.5mm2
(20AWG)
Shielded
Rain Collector
"Rain amount (mm or inch)
Collection area: 200 cm2
(31 inch²)
Resolution: 0.254mm
(0.01"")"
"±2%, Rainfall count
between 0.2-50mm/hr
(0.01-2""/hr)±3%, Rainfall
count between 50-
150mm/hr (2-4""/hr)"
Dry contact
(tipping bucket)
100 meter (330 feet)
---
Rain Detector Rain, No Rain 0.2mm/hr
"Dry contact/0-
5VDC"