EasyManuals Logo

NetApp DS224C Service Guide

NetApp DS224C
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
cluster::> storage show disk -port
PRIMARY PORT SECONDARY PORT TYPE SHELF BAY
-------- ---- --------- ---- ---- ----- ---
1.20.0 A node1:6a.20.0 B SAS 20 0
1.20.1 A node1:6a.20.1 B SAS 20 1
1.21.0 B - - SAS 21 0
1.21.1 B - - SAS 21 1
...
7. The next step depends on the storage disk show -port command output:
If the output shows... Then...
All disk drives in the stack
are connected through path A
and path B except for the
ones in the disk shelves you
disconnected, which are only
connected through path B
Go to the next step.
You successfully bypassed the disk shelves you are removing and
reestablished path A on the remaining disk drives in the stack.
Anything other than the
above
Repeat Step 5 and Step 6.
You must correct the cabling.
8. Complete the following substeps for the disk shelves (in the stack) you are removing:
a. Repeat Step 5 through Step 7 for path B.
Note: When you repeat Step 7 and if you have recabled the stack correctly, you should only
see all remaining disk drives connected through path A and path B.
b. Repeat Step 1 to confirm that your system configuration is the same as before you removed
one or more disk shelves from a stack.
c. Go to the next step.
9. If when you removed ownership from the disk drives (as part of the preparation for this
procedure), you disabled disk ownership automatic assignment, reenable it by entering the
following command; otherwise, go to the next step:
storage disk option modify -autoassign on
For HA pair configurations, you run the command from the clustershell of both controllers.
10. Power off the disk shelves you disconnected and unplug the power cords from the disk shelves.
11. Remove the disk shelves from the rack or cabinet.
To make disk shelves lighter and easier to maneuver, remove the power supplies and IOM12
modules. Avoid removing the disk drives if possible, because excessive handling can lead to
internal damage.
Caution: It is recommended that you use a mechanical hoist or lift if you are moving a fully
populated DS460C disk shelf, which can weigh 249 lb (113 kg).
44
| Service Guide for DS460C, DS224C and DS212C Disk Shelves

Other manuals for NetApp DS224C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp DS224C and is the answer not in the manual?

NetApp DS224C Specifications

General IconGeneral
Form Factor2U
Drive Bays24
Drive Type2.5-inch SAS
Maximum Raw Capacity368 TB
Connectivity12 Gbps SAS
Power SupplyRedundant power supplies
CoolingRedundant fans
Storage TypeHDD and SSD
CompatibilityNetApp FAS and AFF systems