Security Gateway Manual Netgate-8300
BMC Status LED Patterns
Description LED Pattern
BMC Power Applied BMC solid amber
BMC OS Booting BMC flashing blue
BMC Boot Completed/Ready BMC solid blue
Power Supply Unit LED Patterns
Each power supply has a status LED in the upper right corner (not pictured).
Description LED Pattern
Power Applied + Power On PSU solid green
Power Applied + Power Off PSU flashing green
Power Loss to all PSUs PSU off
Power Loss to one PSU
1
PSU flashing amber
Warning Event
2
PSU flashing alternating amber and green
Critical Event
3
PSU solid amber
PSU LED Notes
1.4.3 Rear Panel
The rear panel of the device has items which are not meant to be accessed as often as the front, as the device is intended
to be mounted in a rack.
Fig. 14: Rear view of the Netgate 8300 Security Gateway with key items numbered
The items below are marked with numbers on figure Rear view of the Netgate 8300 Security Gateway with key items
numbered:
Item Description
1 Fan exhaust grills
2 Ground connection
3 Power switch
1
When multiple PSUs are installed.
2
PSU continues operating during warning events. Warning events include: High temperature, power level higher than expected, current higher
than expected, fan operating slower than expected.
3
Critical events cause a PSU to shut down. Critical events include: PSU failure, output over current protection, output over voltage protection,
fan failure.